Share:
Twin Cylinder Shear (OMT)
If you have any questions, please contact us at the first time!
Product category:
Product Keywords:
- Product description
-
Product Advantages
Imported Oil Seal
Uses Hansheng sealing ring to withstand pressure, with three layers of seals to prevent oil leakage.
Distributor Plate
Uses powder metallurgy valve plate, wear-resistant, high precision.
Stator Rotor Set
Precision machined by imported processing centers, flatness error does not exceed 2mm.
Output Shaft
Uses low-carbon alloy steel output shaft, carbonitriding and cyanidation treated for longer life.
Bearing
Uses Simonsi S-type three bearings for strong radial force and high pressure resistance.
Delivery Time
Expedited shipping, delivery time 2-7 days, custom processing accepted.
OMT Series Performance Parameters
Displacement (ml/r) 195 245 315 390 490 625 800 985 Flow (LPM) Max. Continuous 150 150 150 150 150 150 150 150 Intermittent 170 210 225 225 225 225 225 225 Speed (RPM) Max. Continuous 776 615 484 385 308 242 186 155 Intermittent 865 836 699 572 453 354 275 230 Pressure (Mps) Max. Continuous 20.5 20.5 20.5 20.5 17 14 12 12 Intermittent 31 31 31 31 27.5 17 14 14 Torque (N'm) Max. Continuous 572 733 928 1156 1213 1331 1378 1565 Intermittent 852 1176 1356 1633 1878 1368 1645 1877 Conventional Motor Selection
Four-hole Flat Key

Four-hole Spline

Motor Usage Guide
To ensure optimal operation of OMM, OMP, OMR, BM3, BM4, and other cycloid hydraulic motors, the following is recommended:
1. Oil Temperature: Normal operating oil temperature 20°C ~ 60°C, maximum system operating temperature 90°C (should not exceed one hour).
2. Filter and Oil Cleanliness Level: Filter precision is 10-30 microns. It is best to install a magnetic block at the bottom of the oil tank to prevent metal shavings from entering the system. The solid contamination level of the working oil should not exceed 19/16.
3. Oil Viscosity: Kinematic viscosity at 40°C oil temperature is 42-74 mm²/s. Hydraulic oil can be selected based on actual operating and ambient temperatures.
4. Motors can be used in series or parallel. When used in series or parallel, if the back pressure exceeds 10 MPa (speed below 200 RPM), an external drain port must be used to relieve pressure. It is best to connect the external drain port directly to the oil tank.
5. The output shafts of BMS, BMSY, BMT, BMV, BMK6 series motors can withstand significant axial and radial loads.
6. The optimal operating condition for the motor should be chosen between 1/3 and 2/3 of the rated operating condition.
7. To ensure a long service life for the motor, it should first be run at 30% of the rated pressure for about 1 hour when applying load; in any case, ensure the motor is filled with oil before applying load.
Twin Cylinder Shear (OMT)
If you have any questions, please contact us at the first time!
Product category:
Optimization keywords:
Related Products
Product Inquiry
We will contact you within one working day. Please pay attention to your email.